Model Output
(kW)
Current
(A)
Speed
(r/min)
Eff. 100% Eff. 75% Eff. 50% Power
factor
(Φ)
Tn
(N.m)
Tst/Tn
(Times)
Tmin/Tn
(Times)
Tmax/Tn
(Times)
Ist/In
(Times)
Noise
(dB)
Net
weight
(kg)
Inertia
(kg*m²)
Operation
ML800-4 0.37 2.52 1420 66.5 0.96 2.49 2.5 1.5 1.8 5.4 68 8.5 0.001105 SPECIFICATION Drawing
ML801-4 0.55 3.52 1420 71.5 0.95 3.70 2.5 1.61 1.8 5.4 70 9.6 0.001380 SPECIFICATION Drawing Test Report
ML802-4 0.75 4.56 1420 73 0.98 5.04 2.4 1.35 1.64 5.4 70 10.9 0.001656 SPECIFICATION Drawing Test Report
ML803-4 1.1 6.57 1400 73.5 0.99 7.50 2.5 1.53 1.64 5.8 73 0.002206 SPECIFICATION
ML90L2-4 2.2 12.10 1415 80.5 0.98 14.80 2.5 1.09 1.73 6.2 78 0.004226 SPECIFICATION
ML100L2-4 3 16.40 1445 83 0.96 19.83 2.4 1.64 1.8 6.5 78 28.7 0.010543 SPECIFICATION Drawing Test Report
ML112M2-4 4 21.30 1435 83.5 0.98 26.62 2.4 1.2 1.67 6.5 79 32.8 0.014485 SPECIFICATION Drawing Test Report
ML632-6 0.12 1.18 910 45.5 0.97 1.25 3 1.68 1.7 3.8 63 5.9 0.000486 SPECIFICATION
ML711-6 0.18 1.34 930 60 0.97 1.85 2.5 1.77 1.8 4.5 68 6.2 0.000965 SPECIFICATION Drawing Test Report
ML712-6 0.25 1.93 940 58 0.97 2.54 2.3 1.48 1.8 4.6 68 8.1 0.001151 SPECIFICATION
ML801-6 0.37 2.48 935 67 0.97 3.78 2.1 1.5 1.6 5.1 68 10.1 0.001829 SPECIFICATION Drawing Test Report
ML802-6 0.55 3.47 935 71 0.97 5.62 2.2 1.18 1.45 5.3 70 10.8 0.002366 SPECIFICATION Drawing
ML112M-6 2.2 12.00 965 82 0.97 21.77 2.5 1.8 1.73 8.2 75 31.2 0.019523 SPECIFICATION Drawing Test Report
MYC58A2 1.1 7.18 2770 68 0.98 3.79 0.35 0.3 1.7 5 78 9.35 0.000697 SPECIFICATION
MYC58B2 1.5 9.51 2790 70 0.98 5.13 0.35 0.3 1.7 5 80 11.27 0.000900 SPECIFICATION
MYC58C2 1.8 11.10 2790 72 0.98 6.16 0.32 0.28 1.7 5 80 12.39 0.001031 SPECIFICATION

*** This products database now is in a beta version and it may has some blemishes, your kind tolerance, and any of your comment and suggestion would be highly appreciated.

*** Unless otherwise specified, all the technical data in this products database is based on 400V/50Hz (three phase) and 230V/50Hz (single phase). If you have demand for other electrical condition, please contact our sales staff for help.

*** We reserve the right of final explanation and revision for this products database.